How to Make a Leak-Free HVAC Flare

Leak-free HVAC flares: 45 vs 37 degree, why flares crack, and how an eccentric flaring tool helps. Prep steps that pass pressure test first time.

how-to-make-a-leak-free-hvac-flare

How to Make a Leak-Free HVAC Flare: 45° vs 37°, and Why Eccentric Flaring Reduces Leaks

By Alisa Xu, Product Manager — Ningbo Torchmark Hardware Co., Ltd. · Updated 2026-10-10 · LinkedIn
Most refrigerant leaks at a flare joint are not a fitting problem — they are a flaring problem. The good news: a leak-free flare is mostly process. This guide is written for HVAC contractors who are tired of callback visits and for distributors choosing which flaring tools to put in front of their customers.
If you only remember one thing: a flare fails at commissioning because the wall thinned, the seat was uneven, or the tubing was not prepped. Fix those three and pressure test stops being a coin toss.

Flare types: 45° vs 37°, single vs double

Before technique, know which flare the job actually needs:
  • 45° single flare — the HVAC/R and refrigeration standard for soft copper line sets in most markets. This is what the FT-806AM-F produces.
  • 37° (AN) flare — used for automotive, hydraulic and some aerospace lines. It is a different seat angle; a 45° flare will not seal correctly in a 37° fitting, and vice versa.
  • Double flare — common on brake lines (SAE J533). It folds the tube back on itself for a thicker, crack-resistant seat. Not normally used on HVAC/R copper, where a clean 45° single flare is correct.
Specifying the wrong angle is the fastest way to a joint that looks fine and leaks under pressure. Match the tool to the fitting, not to habit.

Why flares actually leak

We see the same failure modes on returned jobs and in sample reviews:
  1. Wall thinning at the lip. A centred cone presses the tube outward and stretches the wall thin. Under refrigerant pressure the thin lip cracks or creeps.
  1. An uneven or off-centre seat. Tube not squared, or not clamped straight, so the flare is not concentric with the fitting. It seals on one side and weeps on the other.
  1. Bad prep. Burrs left inside the tube restrict flow and trap debris; outside not deburred, the flare rides up the cone.
  1. Over- or under-torque at assembly. Too loose weeps; too tight cracks the flare or distorts the nut.
  1. Dirt or no lubricant. Dry flaring drags the cone and scores the seat.

Eccentric vs standard flaring tools

A standard flaring tool uses a centred cone. An eccentric (offset) flaring tool — like the FT-806AM-F — rides the tube wall and forms the flare by rolling rather than pressing. The practical effect:
  • The wall thickness at the flare lip stays closer to the original tube wall, so it is less likely to thin and crack.
  • The seat is smoother and more concentric, which is what actually seals against the fitting.
  • Results are more repeatable across a batch — important when a distributor is shipping the same tool to hundreds of technicians.
This is why we lead our flaring range with the eccentric kit: for a contractor the payoff is fewer leaks at commissioning; for a distributor the payoff is fewer warranty returns.

Step-by-step to a flare that passes first time

  1. Cut square. Use a sharp tube cutter, not a hacksaw. A square cut is the start of a concentric flare.
  1. Ream both sides. Remove the internal burr (restricts flow, traps swarf) and deburr the outside edge so the tube rides the cone cleanly.
  1. Clean and lubricate. Wipe the tube and put a light film of refrigeration oil on the cone. Dry flaring scores the seat.
  1. Clamp straight. Seat the tube flush with the top of the correct bar, tube square to the bar face. No tilt.
  1. Flare with even pressure. Turn the cone in smoothly; let the eccentric roll the flare rather than forcing it.
  1. Inspect. The flare should be a smooth, concentric bell with no cracks, splits or thin spots at the lip. Hold it to the light — a uniform edge is the goal.
  1. Assemble correctly. Clean the fitting, use the right torque on the nut, and pressure-test with nitrogen before charging.

Choosing a flaring tool for distribution or contracting

If you buy tools to resell, or equip a crew, look past the headline photo:
  • One kit, both standards. A metric + SAE bar set covers most of a mixed market from a single SKU.
  • What ships with it. Cutter and reamer in the same case means the technician actually does step 1–2 instead of skipping them.
  • Repeatability. Eccentric forming matters most when the tool is used hundreds of times by different hands.
  • Confirmed supply. For private label, confirm samples against your specification before bulk — that is what separates a brand from a gamble.
Once the seating face is right, the remaining variables are tool type, flare angle and tube condition — the tube flaring tools complete guide sets out that selection framework.

Frequently asked questions

Do I need a double flare for HVAC/R copper?
Usually no. HVAC/R soft copper line sets use a 45° single flare. Double flares belong to brake lines. Using the wrong type is a common leak cause.
Can I use a 45° flare in a 37° (AN) fitting?
No — the seat angles do not match and the joint will weep. Use a 37° tool for AN/automotive applications and keep 45° for HVAC/R.
Why does my flare crack at the lip?
Most often wall thinning from a centred-press tool, or over-flaring. An eccentric roller-style tool keeps the wall more even; also check you are not over-torquing at assembly.
Is reaming really necessary?
Yes. The internal burr restricts flow and traps debris; a poor outside edge makes the tube ride the cone unevenly. Reaming is steps 1–2 of a leak-free flare.
Which TORCHMARK tool makes a 45° flare?
The FT-806AM-F eccentric flaring tool kit produces a 45° flare with metric + SAE bars, cutter and reamer included. See the FT-806AM-F product page.
Related product: Eccentric Flaring Tool Kit (45°) — FT-806AM-F — metric + SAE bars, 4–32 mm cutter and reamer, OEM/private-label, MOQ from 500 sets. Explore the range: HVAC Flaring & Tube Tools Explore the full TORCHMARK tool range Flaring, drain cleaning and riveting — product pages and B2B buying guides in one place.Browse all products → Where a flare fails, and what to check
Most leaking flares are not caused by the flaring tool. They are caused by what happened before the flare was formed, or by a flare made on the wrong clamping size. The table below maps the symptom to the cause most commonly behind it.
Symptom
Usual cause
What to check first
Flare cracks at the edge
Tube cut out of square, or work-hardened tube
Cut square with a tube cutter, deburr, anneal if hard drawn
Uneven contact band
Formed on the nearest available hole, not the exact OD
Confirm the tube OD is actually listed on the model
Flare seats but rocks
Wrong flare angle for the fitting
Confirm the fitting standard, not just the 45° angle
Split down the wall
Wall thickness too thin, or over-formed
State wall thickness on the enquiry; check forming depth
Weeps under pressure only
Contact band correct in shape, wrong in width
Compare against a flare made on a known-correct setup
Nut will not pull up
Flare formed oversize
Check clamp seating and tube position in the block
Configurations and listed sizes are on the CT-203A / CT-203M, CT-190A / CT-190M and CT-103A / CT-103M pages.
Questions installers ask about flare leaks

Do I need to deburr before flaring?

Yes, inside and out. A burr on the cut face prevents the flare seating evenly and is one of the most common causes of a slow weep.

Can I flare hard drawn copper without annealing?

It is more prone to cracking. Anneal first where the specification allows it, and state the tube temper on your enquiry so the sample is tested on the right material.

Does a 45-degree tool suit every connection?

No. 45 degrees is the flare angle, not a fitting standard. Refrigeration, gas and brake connections each have their own requirements — confirm the application.

Why does my flare look right but still leak?

Usually because it was formed on the nearest available hole rather than the exact outside diameter. The shape looks correct; the contact band does not seat.

Which model covers 25 mm?

CT-103M, which lists 22, 25 and 28 mm. CT-203M lists 16, 19, 22 and 28 mm and does not include 25 mm.

Should I use an eccentric flaring tool?

Where access is the constraint rather than diameter — tight spaces where a standard bar and yoke will not swing. See the CT-806A.

Related products

Flaring

Cutting and bending

Related guides

Request a quote

Send the tube sizes and measurement system, tube material and wall thickness, model preference, quantity and destination port. We will confirm coverage and return price, MOQ and lead time.
amy@longrunhardware.com · alisa@longrunhardware.com · · WhatsApp +86 158 6745 7689Small trial orders for flaring configurations
If you are adding flare tools to your range, a small trial order covering the tube sizes and cone types you actually stock is enough to check fit and demand. The applicable minimum is confirmed for each item in the quotation.
Send the tube diameters, the 45° SAE or 37° JIC cone you need, and your first-order quantity, and we will confirm the matching configuration, packing and terms per order.