Choose a copper tube flaring tool by its listed tube sizes and flare standard, not by kit count. Check where CT-190, CT-103 and CT-203 leave metric coverage gaps before the RFQ.

copper-tube-flaring-tool-buying-guide
Flare type and application Define the required flare format, tubing material and typical installation work. The tool design must match the intended connection standard. Clamping and alignment Stable clamping helps prevent tube slippage and off-center flares. Evaluate bar markings, positioning speed, grip consistency and release after forming. Operator effort and repeatability For frequent field use, compare handle leverage, cone movement and the number of steps required. Sample testing should measure consistency across multiple tube sizes and operators.
Kit configuration and packaging Clarify whether the quotation includes the tool only, a case, adapters or tube-preparation accessories. Confirm carton quantity, instruction language, barcode, logo and package artwork before production. Recommended Sample Evaluation Use the intended copper tube and complete repeated flares in every required size. Check for cracking, uneven walls, tube slippage, visible scoring and fit with the target connector. Record results so production inspection uses the same acceptance criteria. RFQ Checklist • Required tube sizes and measurement system • Flare type and application market • Tool-only or complete kit configuration • Target quantity and destination country • Private-label logo, color and packaging • Sample and inspection requirements Mixed orders are welcome. Samples are charged; sample shipping costs are refunded after an order is placed. Typical lead time is 15–45 days, subject to the selected products and packaging. Send your size range, quantities and destination country to start a quotation. For an inch-size option, confirm tubing and fitting compatibility before sampling the CT-806A 45-degree eccentric flaring tool. Request a quotation:  https://www.nbtorchmark.com/contact-us Browse HVAC tools:  https://www.nbtorchmark.com/products 
ABOUT THE AUTHOR Alisa Xu — Product Manager, Ningbo Torchmark Hardware Co., Ltd. Phone: 0086-13429254575 LinkedIn: https://www.linkedin.com/in/alisasourcing/Configurations at a glance
Once the buying criteria above are settled, the practical question is which listed configuration covers the sizes your market installs. The table below sets out the 45-degree flaring tools in the current catalogue and the sizes each one lists.
Model
Listed sizes
Flare angle
Pcs / case
Carton
CT-190A
3/16, 1/4, 5/16, 3/8, 7/16, 1/2, 5/8 in
45°
20
27 × 20 × 27 cm
CT-190M
5, 6, 8, 10, 12, 14, 16 mm
45°
20
27 × 20 × 27 cm
CT-203A
5/8, 3/4, 7/8, 1, 1-1/8 in
45°
10
31.5 × 17 × 14.5 cm
CT-203M
16, 19, 22, 28 mm
45°
10
31.5 × 17 × 14.5 cm
CT-103A
7/8, 1, 1-1/8 in
45°
10
31.5 × 17 × 14.5 cm
CT-103M
22, 25, 28 mm
45°
10
31.5 × 17 × 14.5 cm
Two points to note before you order. CT-203M does not list 25 mm — a 25 mm requirement moves to CT-103M. And the catalogue illustrations are labelled CT-190, CT-203 and CT-103 without the suffix, so the A (inch) or M (metric) suffix must be stated on the order.

Choosing by the work your customers do

Residential split-system installation

Dominated by the common refrigeration diameters. CT-203A or CT-203M is the usual starting configuration, and CT-190A or CT-190M covers the smaller sizes that appear in the same van. Many distributors stock both.

Commercial and larger-diameter work

CT-103A and CT-103M handle the large listed sizes, and CT-103M is the configuration that includes 25 mm. Where access rather than diameter is the constraint, an eccentric tool changes how the flare is formed — see the CT-806A eccentric flaring tool.

Service and maintenance ranges

Breadth beats depth. CT-190 packs 20 per case and covers seven sizes in each system, which suits a range bought in higher frequency at a lower price point.

Getting a flare that does not leak

Cut square and deburr first

Most leaking flares start with a bad cut. A tube cut out of square presents an uneven face to the cone. Use a proper tube cutter — the 168 mm copper tubing cutter is the standard shop item — and deburr inside and out before flaring.

Match tube temper and wall thickness

Soft copper and hard drawn copper form differently, and thin-wall tube splits more readily. State both on the enquiry so the sample is tested on the right material.

Check the contact band, not just the shape

An even continuous contact band that seats without rocking is the pass condition. A flare can look correct and still weep if it was formed on the nearest available hole. The full procedure is in how to make a leak-free HVAC flare.

What to specify in the enquiry

The fields that decide the quote

Every tube outside diameter with its measurement system, the fitting standard or application, tube material and wall thickness, full model suffix, kit contents, packing quantity, packaging format and an acceptance criterion. Our RFQ specification checklist gives the block to paste into an enquiry.

Sample approval

Arrange a sample on the exact sizes and material, agree the test method, then release production. The sequence is set out in the sample approval checklist.

Packing, branding and freight

Reading the carton data

CT-190 packs 20 per case at 27 × 20 × 27 cm; the CT-203 and CT-103 configurations pack 10 per case at 31.5 × 17 × 14.5 cm. Work landed cost per tool from those figures rather than per carton, and confirm the figure for the approved SKU.

Private label

Logo position, barcode, instruction language and packaging format are specified before production. Send artwork with the RFQ so printing is quoted with the tools.

Accessories and repeat lines

Replacement components and related items are on the flaring tool accessories page. Listing them alongside the tool creates the repeat order.

Frequently asked questions

Which configuration suits a mixed inch and metric market?

Both. The A and M variants are separate products, so stocking CT-203A and CT-203M covers the common diameters in each system without one substituting for the other.

Does CT-203M cover 25 mm?

No — its listed sizes are 16, 19, 22 and 28 mm. Use CT-103M for 25 mm, which lists 22, 25 and 28 mm.

How many pieces per case?

20 for CT-190 configurations, 10 for CT-203 and CT-103. Confirm at quotation because bespoke programmes can differ.

Do we need an eccentric flaring tool?

Where access is the constraint rather than diameter, yes — the CT-806A forms the flare differently and reaches where a standard bar and yoke cannot.

What else does an installer need alongside the flaring tool?

A tube cutter, a deburring tool and a bender. See the TB365 tube bender set and cutter and bender buying guide.

Can we mix configurations in one container?

Yes. Mixed containers are the usual way to test which configuration a market prefers before committing to a single line.

Where to go next

Request a quote

Send the tube sizes and measurement system, tube material, model preference, kit contents, packaging, quantity and destination port. We will confirm coverage and return price, MOQ, lead time and sample cost in one reply.
amy@longrunhardware.com · alisa@longrunhardware.com · · WhatsApp +86 158 6745 7689Small trial orders for flaring configurations
If you are adding flare tools to your range, a small trial order covering the tube sizes and cone types you actually stock is enough to check fit and demand. The applicable minimum is confirmed for each item in the quotation.
Send the tube diameters, the 45° SAE or 37° JIC cone you need, and your first-order quantity, and we will confirm the matching configuration, packing and terms per order.

Read next

More from the journal

Keep readers moving through related announcements, stories, and field notes.