Eccentric Flaring Tool Kit (45°) — FT-806AM-F
By Alisa Xu · Product Manager, Ningbo Torchmark Hardware Co., Ltd. · LinkedIn A precision 45° flaring kit for HVAC/R and refrigeration copper & aluminum tubing, supplied with metric and SAE bars, a tube cutter and a reamer.
A leaking flare is the most common cause of refrigerant loss and callback visits on a new HVAC/R install. The FT-806AM-F uses an eccentric (offset) flaring mechanism that rolls the flare instead of pressing it — so the tube wall stays closer to its original thickness, the seat is more uniform, and the joint seats cleanly against the fitting on the first try.
Built for distributors, importers and private-label brands that need a consistent tool across mixed metric and imperial tubing, the kit ships with both bar sets, a 4–32 mm tube cutter and a reamer in one case. We confirm samples against your specification before production, so what your customers unbox matches what you approved.
Specification
| |
|---|
| 45° (standard for HVAC/R & refrigeration copper) |
|---|
| Metric + SAE (covers common HVAC/R and plumbing tube sizes) |
|---|
| Flaring yoke with eccentric cone, metric bar set, SAE bar set, tube cutter 4–32 mm, reamer |
|---|
| Soft copper, aluminum, and thin-wall mild steel (confirm size range per bar set) |
|---|
| HVAC/R line sets, refrigeration service, plumbing supply connections, gas lines |
|---|
| Blow-mould / custom case; OEM & private-label branding and manuals available |
|---|
| From 500 sets (mixed allocation supported by agreement) |
|---|
| Paid samples available; spec confirmed before bulk production |
|---|
| TORCHMARK (Ningbo Torchmark Hardware Co., Ltd.) |
|---|
Exact bar sizes and material limits should be confirmed against the physical catalogue / your RFQ — we verify the supplied bar and adapter configuration with you before quoting, as noted on the product page.
Why eccentric flaring, not a standard press flare?
On a conventional flaring tool the cone is centred and the tube is squeezed outward. That thins the wall at the flare lip and, with harder or thin-wall tubing, can start a hairline crack you won't see until the system is charged. An eccentric cone rides the tube wall and forms the flare by rolling, which keeps wall thickness more even and produces a smoother, more concentric seat.
For a distributor or contractor, the practical payoff is fewer leaks at commissioning and fewer warranty returns. That is the difference buyers actually pay for — and the reason we lead the flaring range with this kit.
Built for distributor and private-label buying
- One kit, two standards. Metric and SAE bars mean one SKU covers most of your market instead of two.
- Confirmed before bulk. Our workflow includes sample evaluation and specification confirmation, then production follow-up and a pre-shipment check.
- Brand-ready. Custom logo, case colour, labelling and manuals where applicable; export packaging coordinated with your team.
- Mixed orders. MOQ from 500 sets with mixed allocation by agreement, so you can build a flaring + bending + riveting assortment from one supplier.
From our workshop
Photos from our Ningbo, China workshop and facility. We are a manufacturer, not a trading middleman — so specification and packaging are confirmed with the people who make the tools.
Buying for resale or private label? Send your target model, sizes, quantity and market. We return a focused quotation with confirmed specification and lead time.Request a quote Frequently asked questions
What tube sizes does the FT-806AM-F cover?
The kit ships with metric and SAE bar sets for common HVAC/R and plumbing copper sizes. Confirm the exact bar range for your market when you request a quote — we verify the supplied bar and adapter configuration before quoting.
45° or 37° — which do I need?
For HVAC/R and refrigeration copper in most markets the standard is 45°. 37° (AN) is used for automotive and some hydraulic lines. This kit is a 45° tool; tell us if your market needs 37° and we will confirm the right model.
Does it flare aluminum and steel, or copper only?
It is built for soft copper and aluminum, and thin-wall mild steel within the bar size range. Hard or thick-wall steel is not recommended — ask us for the correct tool for that application.
What is the MOQ and can I mix models?
MOQ starts from 500 sets, with mixed allocation supported by agreement so you can combine flaring, bending and riveting tools in one shipment.
Can you do OEM / private label?
Yes. Custom logo, case colour, labelling and manuals are available where applicable, and we confirm samples against your specification before production.
Can I get samples first?
Paid samples are available. Sample cost and delivery are confirmed per model and destination.
Related: how to get a leak-free flare every time
Explore the full TORCHMARK tool range Flaring, drain cleaning and riveting — product pages and B2B buying guides in one place.Browse all products → Talk to our export team Send the model numbers, quantities, packaging requirement and destination port, and we will quote price, MOQ, lead time and sample cost in one reply.
The value of a kit is in the parts that would otherwise be separate order lines. Knowing what is in the case is also how you decide whether the kit or the single tool is the better shelf item.
The flaring yoke and eccentric cone
The eccentric cone rolls the flare rather than pressing it, which reduces the force needed and gives a more even wall. That is the reason this configuration is used where flare quality is checked rather than assumed.
The metric and SAE bar sets
Both bar sets are included, so one kit covers inch and metric tube. Confirm the size list for each set on the sample, because the two standards are cut separately.
The tube cutter and reamer
The kit includes a tube cutter for 4 to 32 mm and a reamer. Treating them as consumables is sensible, since the cutter wheel and reamer are the parts that wear first in trade use.
The case
Blow-mould case as standard, with a custom case option for private label. The case is the part a retail buyer judges first, so say which you want before the run.
Specification reference
These are the published lines for this kit. Where a value depends on the bar set or the order, it is confirmed on the sample approval rather than assumed.
| |
| |
| 45 degrees, standard for HVAC/R and refrigeration copper |
| Metric plus SAE, covering common HVAC/R and plumbing tube sizes |
| Flaring yoke with eccentric cone, metric bar set, SAE bar set, tube cutter 4 to 32 mm, reamer |
| Soft copper, aluminium and thin-wall mild steel, size range per bar set |
| HVAC/R line sets, refrigeration service, plumbing supply connections, gas lines |
| Blow-mould or custom case, OEM and private-label branding and manuals available |
| From 500 sets, mixed allocation supported by agreement |
Where a kit is the wrong answer
A kit costs more per unit than a single tool and takes more shelf space. Three situations suit the single configuration better.
When the buyer already owns a cutter
When the channel is price-led
At the entry price point a single configuration wins on the shelf. Kits sell where the buyer values completeness over the lowest ticket price.
When only one size is ever used
If a customer flares one size all day, a dedicated tool is faster than changing bars. The single-size configurations are listed on the CT-190A / CT-190M page. Checks to run on the sample kit
A kit has more parts to get wrong than a single tool, so the sample check should cover each one.
Make a flare in both bar sets
Flare one metric size and one SAE size. The two sets are cut separately and a mismatch is the most common kit defect.
Check the eccentric cone rotates freely
The cone is the part that does the work. It should turn without play and without marking the tube face.
Test the cutter on the largest size
The cutter is listed to 32 mm. Cut at the top of the range on the sample, because capacity problems show at the limit rather than the middle.
Confirm the case and the manual
Check the case closes with every part in place, and confirm the manual language if the kit is for retail.
Ordering, packing and OEM terms
Questions buyers ask about the FT-806AM-F kit
Does the kit cover both metric and inch tube?
Yes, both the metric and the SAE bar sets are included. Confirm the size list for each set on the sample before a bulk order.
What is the largest tube the cutter handles?
The included cutter is listed for 4 to 32 mm. Test it at the top of the range on the sample, because capacity issues appear at the limit.
Which tube materials can be flared?
Soft copper, aluminium and thin-wall mild steel, with the size range confirmed per bar set. Suitability for a specific material should be checked on the sample.
Is the flare angle 45 degrees?
Yes, 45 degrees, which is the standard for HVAC/R and refrigeration copper. Confirm the angle along with the size list on the sample approval.
Can the case be branded for retail?
Yes, OEM and private-label branding and manuals are available on a custom case. Say so at the enquiry stage because it affects lead time.
What is the minimum order for the kit?
From 500 sets, with mixed allocation supported by agreement. Samples are paid and the specification is confirmed before bulk production.
Request a quotation for the FT-806AM-F kit